THE 5-SECOND TRICK FOR DP50RB

The 5-Second Trick For Dp50rb

The 5-Second Trick For Dp50rb

Blog Article

Assistance 4D probe; acknowledge the probe through the ID code; change the 4D travel signal by using the  electrical relay to produce the 4D probe perform Generally. 4.two.two Key board The main board might be divided into two pieces: entrance-close of the principle board and again-conclusion of the most crucial board.

Greatest 4 periods tasking for a single transmitted beam, leading to superb time resolution and higher frame amount.

Get an entire and prolonged perspective from the anatomical structure via panoramic imaging coupled with velocity indication and forward/backward scan capability producing scanning a lot easier, smoother and more controllable.

This manual may referring to information and facts safeguarded by copyright or patents and doesn't Express any license beneath the patent legal rights or copyright of Mindray, or of Other individuals. Web site 9: Statement

Minimize off cable ties connecting the key device within the Screen by diagonal reducing pliers, and after that pull out the corresponding cable plugs.

Whenever you cease the scanning along with the picture seize, it is best to electric power off the technique and disconnect the technique through the AC electricity provide, then pull out AC energy cables. Website page 109: Battery Connecting Board

The chapter provides the method to validate primary function and overall performance of product. This is only useful for reference, not preventive execution. Purpose checking and screening of this section shall be performed by Mindray services engineers plus the user alongside one another. Website page sixty six: General Examination

Explore much better diagnostic facts through prolonged look at of the anatomical structure on all convex probes.

Permits usage of various scanned angles to form a single graphic, causing Improved contrast resolution and enhanced visualization

Purpose: To the back again-conclude of the leading board, a Distinctive monitor IC is used to monitor sign voltages  and clock battery electricity that happen to be furnished to the leading board by the primary device box electricity supply module.

Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.

Discover far better diagnostic facts as a result of prolonged view from the anatomical structure on all linear probes

General performance Test five.5.one Exam System Resolution Detection depth Geometric Posture Accuracy Blackout location check Record the Test visuals 5.five.2 Test Content material The impression applied here is just for reference, persist with the picture effect in the true NOTE: problem. Necessities: Screen: established the contrast and brightness for the clinical software benefit (or even the default position) Operation natural environment: dark place, simulating the clinical application environment. Page 76 In issue which the transverse resolution screening targets are horizontally shown, history the negligible length of two targets which might be Plainly identified. Repeat the Procedure higher than for that transverse resolution tests targets at other depths. As shown in determine under. Axial resolution ... Web page seventy seven When utilizing the convex probe, keep the transverse resolution tests targets to notice: be displayed close to the midline. When utilizing a linear probe with steer purpose, will not turn on the steer perform when perform the transverse resolution examination. Zoom in the region wherever the targets Positioned if essential. The diameter with the concentrate on stage at a particular depth is equal to the transverse resolution within the depth. Web site seventy eight five.

Your Software for further biopsy: letting adjustments into the scan line to achieve improved visibility of your needle, nerves and small vessels, guaranteeing the continuity of all details.

NOTE: Be sure that you may pull out and drive into the Dp50rb login IO board sockets vertically when pulling out and assembling the IO board assembly on the situation in the manage. Eliminate panhead screws with washers M3X6 (four) accustomed to protected the IO board, and afterwards you might consider out the IO board. Page 116 Take away panhead screws with washers (two M3X6) that happen to be fixed on the leading device, just take out the higher baffle and after that pull out two cables connecting the key board to the power module assembly.

Report this page